Tunnel Fireproofing roof Board - RFBFT
Tunnel Fireproofing roof Board, 1,100% asbestos free, 2,Fireproof board, 3.Non-combustible,Mgo board, 4.Green product - details see: https://www.buildingsupplieshub.com/tunnel-fireproofing-roof-board-10025515
Place of Origin: Shanghai China (Mainland) | Brand Name: Jinyida | Model Number: RFBFT | Basic color: Grey |
Non-combustible: Class A | Size: 2,440mm*1,220mm | Thickness: 10mm | Security: 100% Asbestos Free |
Density: 0.8-1.12g/cm3 | Deformation rate: ≤0.2 | Water absorption rate: ≤10.0% | Type: Magnesium Oxide Board |
Certification: CE,ISO |
Tunnel fireproofing roof board
Description | Sidewall fireproofing board of tunnel |
Raw Materials | magnesium oxide, magnesium chloride |
Standard Size | 1220mm×2440mm |
Thickness | 10mm |
Basic Color | white |
Manufacturing Standard | GA160-2004 |
Fire Resistance | Incombustibility Class A |
Packing | Wooden pallet |
Trade Terms | FOB SHANGHAI, CNF, CIF,CFR |
Payment | T/T, L/C at sight |
Leadtime | 15days after receipt of the T/T deposit or L/C. |
Main Characteristic | 1.Fire proof and non combustibility |
2.Non-flammability: GB25970 grade A | |
3.Waterproof: resistant to deformation in wet environments | |
4. Weight: Light weight,(volume weight: 1.02-1.06g/cm3) | |
5. Strength: Bendable and impact resistant | |
6.Invariability: Resistant to deformation in wet, hot and dry conditions | |
7. Aging resistance | |
8.Heat Resistance: Thermal conductivity of 0.020W/(m.°C) | |
9.Durability: Resistance to halogen accumulation, long lasting strength | |
10.Cold resistance: can be used at 40 degree | |
11.Installation: Easy to work, fix and decorate | |
12.Environmentally friendly |
Technical parameters of fireproofing board for tunnel
Items | Items to be inspected | Technical requirements and parameter | ||
1 | Areal density(kg/m2) | ≤25 | ||
2 | Allowable difference between edge flatness and diagonal line | Not inferior to requirements of GA160-2004,4.3.3 | ||
3 | Bend strength in dry condition(Mpa) | Satisfies the requirements of GA160-2004,4.4 | ||
4 | Bend strength in condition of saturated moisture absorption(Mpa) | No less than 70% of bend strength in dry condition | ||
5 | Deformation rate after moisture absorption(%) | ≤0.20 | ||
6 | Performance of anti-dehylogenation | No bead and no damp | ||
7 | Toxicity of generated fume | No inferior to ZA1 of GB/T20285-2006 | ||
8 | Water resistance(h) | ≥720 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed | ||||
9 | Acid resistance(h) | ≥360 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed | ||||
10 | Alkaline resistance(h) | ≥360 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed | ||||
11 | Moisture and heat resistance (h) | ≥720 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed | ||||
12 | Freeze thawing resistance periodicity (times) | ≥15 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed | ||||
13 | Salt mist corrosion resistance(h) | ≥30 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed. | ||||
In case the decorated board is made of metal,the metal surface shall be free of rust. | ||||
14 | Burning performance | Not inferior to requirements of grade B of GB 8624-2006 | ||
15 | Water absorption rate (%) | ≤12.0 | ||
16 | fire resistance performance(h) | standard | Limit of fire resistance(h) | ≥2.0 |
HC type | Limit of fire resistance(h) | ≥2.0 | ||
RABT type | Limit of fire resistance(h) | During temperature rise≥2 | ||
During temperature drop≥1.83 |
Application : mainly used for road, mountain tunnels, suitable for fire resistance 3.83 hours (RABT standard) for I Type II tunnel, and non-load-bearing structure of the tunnel fire protection.
Installation case
Plant photo
quality certificate
test report
sample room
decoration
Contact us :It takes 10 minutes to come to our factory by car.
Packaging Detail:Standard Wooden pallet |
Delivery Detail:15days after receipt of the T/T deposit or L/C. |