spray projection plaster Uni-Plaster M - M
Place of Origin: Saudi Arabia | Brand Name: Uni-Plaster M | Model Number: M | Final Setting Time: 180 minutes |
Consumption: 11 kg/m2 for 1 cm thickness | Compressive Strength: >2.8 MPa | Thermal conductivity: 0.39 W/ mK | Color (L): >80 |
Standard: EN13279-1-B4/50/2 | Binder: gypsum | One coat thickness: 8 to 25 mm |
UNI-PLASTER M is modified gypsum plaster ready to use, designed for machine application to most internal backgrounds such as red brick, concrete block, concrete face and aerated-concrete.
• Formulated with special additives to control working and setting characteristics
• A smooth, very hard and brilliant surface for walls and ceilings
• Good air tightness for improved thermal insulation
• Hardening and full reaction takes place in 6 hours
APPLICATION:
• Clean wall from all debris and fill holes bigger than 2 cm with UN I-PLASTER M or any other mortar
• On smooth concrete face use bonding compound before applying UNI-PLASTER M (recommended UNI-BOND)
• Add bags content continually into running spray machine and adjust water flow valve to 5-6 liter for every 10 kg of
UNI-PLASTER M
• Spray from bottom to top in lines at horizontal motion
• Level UNI-PLASTER M with aluminum bar
• When plaster is harder than finger skin, spray water with brush and use foam rubber sponge to polish plaster face motion to turn it into soft paste
• After 5 minutes of last step compact and finish with steel trowel
• If necessary when plaster is hard, spray water with brush and use sharp steel trowel to polish surface and cut any
in circular high spots
RECOMMENDATIONS:
Apply in one coat at thickness of mm 8 mm and max 25mm
• Do not apply at temperatures below 4.50 C
• Use clean water. Do not use water containing UNI-PLASTER M
• Spray water on dry and hot surfaces before applying UNI-PLASTER M
• Plaster machine and application tools should be cleaned
• Use internally only
STORAGE CONDITIONS:
• Store in a dry place at no more than 20 layers
• Use within one year after the date of production
TECHNICAL SPECIFICATIONS:
Water / Plaster ratio 5- 6 liter for every 10 kg of UNI-PLASTER M
Final Setting Time 180 minutes
Consumption 11 kg/m2 for 1 cm thickness
Compressive Strength >2.8 MPa
Surface Hardness 60 SHORE D
Dry Density (after installation on the wall) 1100 kg/m3 ±%5
Thermal conductivity < 0.39 W/ mK
Oversize 2mm 0%
Bag net weight 35 kg ±%2
Standard EN13279-1-B4/50/2
Packaging Detail:35 kg |
Delivery Detail:3 days |