Place of Origin: SIC,sichuan,china China (Mainland)Brand Name: AnltModel Number: AnltFF1RType: Floor Heating Parts,infrared radiant floor heating
Floor Heating Part Type: Floor Heating MatsJacket: PVCInsulation Material: silicon rubberConductor Material: Copper Alloy
infrared radiant floor heating
contact supplier for infrared radiant floor heating


infrared radiant floor heating :

Advanced demostic technical position& Great safety
Energy saving&Long-time working&Environment protecting

Application:

Public&office buildings,Club,Snow melting,Animal husbandry system

Standard:

ALTGV1R ALTGG1R ALTGV2R

Certifacation:

ISO90012000 ROHS CE

Voltage:220V

Power per metre: 18W

We can also produce based on cosumers' request.

Single comductor floor heating cable

StandardTotle resistence(ohm)Length(m)Total PowerW
ALTGV(GG)1R161.3316.7300
12122.2400
96.827.8500
80.6733.3600
69.1438.9700
56.9447.2850
48.455.61000
38.41701260
30.2588.91600
27.597.81760
24.2111.12000
22122.22200
20.17133.32400
18.62144.42600
17.29155.62800
16.13166.73000
specificationpower(w/pcs)Voltage(V)power(w/m)resistance(Ω)length(m)area)m2
ALT FF1R-150

-150/12-1.0

15022012322.6712.52×0.5=1.0
ALT FF1R-150

-225/12-1.5

22522012215.1118.83×0.5=1.5
ALT FF1R-150

-300/12-2.0

30022012161.3325.04×0.5=2.0
ALT FF1R-150

-450/12-3.0

45022012107.5637.56×0.5=3.0
ALT FF1R-150

-600/12-4.0

6002201280.6750.08×0.5=4.0
ALT FF1R-150

-750/12-5.0

7502201264.5362.510×0.5=5.0
ALT FF1R-150

-900/12-6.0

9002201253.7875.012×0.5=6.0
ALT FF1R-150

-1200/12-8.0

12002201240.33100.016×0.5=8.0

prodution process :

some samples :

office and workshop:

certifates:

Frequently Asked Questions

Q:Is there electromagnetic radiation to the human body by using ANLT Floor Heating System?

A:The heating cable of ANLT Heating Cable Floor Radiant Heating System adopts the double-screen construction,can effectively reduce the electromagnetic radiation,so it is very safe and will not produce electromagnetic radiation on the human body.

Q:Does the cable have the electric-leakage problem ?

A:The electric heating products lack of strict quality control and application experience may have hidden danger of electric leakage.But ANLT heating cable uses the sophisticated design and production technology,with the multiple safe protection devices such as the electric-leakage protection,so it can be assured for safe use.

Q:Dose ANLT Heating Cable Floor Radiant Heating System have huge power consumption ?

A:The power consumption of ANLT Heating Cable Floor Radiant Heating System depends on many factors such as the hours of use,temperature setting ,and heating conservation,and intelligent temperature control system,you can save huge electricity bills.

Q:What’s the difference between ANLT Heating Cable Floor Radiant Heating System and traditional hot-water heating system ?

A:The structure of ANLT Heating Cable Floor Radiant Heating System is simple,temperature of the room is more even,temperature control is more accurate too,in addition,for comparing,the hot-water heating system has the disadvantages of the difficult of sectional temperature control and huge investment on installation;the heating temperature is different too,hot-water system has a highter temperature but having a higher requirement for the floor materials

Q:Which are the requirements for installing the ANLT Heating Cable Floor Radiant Heating System?

A:It is very simple for installation,only need a certain height of the structure layer,including heat-conservation layer,generally about 3-5 centimeters. In addition,for safety requirement,you need certain power capacity installation.

Q:How long will it last ?

A:The ANLT Heating Cable products provide 12 years’ quality guarantee.According to different operating conditions ,the whole heating system can be used for 50 years without maintenance.

Q:What are the main difference between ANLT Heating Cable Floor Radiant Heating System and traditional heating system ?

A:It is more comfortable by using ANLT Heating Cable Floor Radiant Heating System than the traditional heating system; ANLT Heating system adopts the “invisible installation”,which will not impact the decoration of the internal design of your houses;temperature in different rooms can be controlled separately;without noise impace and dry feeling.

Q:What are the floor material requirements for installing the ANLT Heating Cable Floor Radiant Heating System ?

A:Many kinds of floor materials can be used for installing ANLT Heating Cable Floor Radiant Heating System.Such as ceramic tiles and marbles,which distribute the temperature fast and provide most comfortable feeling.

Packaging Detail:infrared radiant floor heating with normal package
Delivery Detail:within two weeks after payment

Related Product for infrared radiant floor heating