high quality stainless rotary damper - LF-33
1. soft closing, can support 4kgs, 2. more than 50000 cycles, 3. pass TUV test, ISO9001/14001, 4. stainless steel, high class - details see: https://www.buildingsupplieshub.com/high-quality-stainless-rotary-damper-10019454
Place of Origin: Guangdong China (Mainland) | Brand Name: Longji | Model Number: LF-33 | Feature: Slow-Close Toilet Seats |
Toilet Seat Material: All | Toilet Seat Shape: All | Toilet Seat Type: Closed Front | Resistance torque range: 10-30 kgf.cm |
Life: more than 80000 cycles | Housing Material: stainless steel | Inner Material: PA | Color: Black |
TUV test: passed | Quality: ISO9001/14001 |
2. more than 30000 cycles
3. pass TUV test, ISO9001/14001
4. stainless steel, high class
We owe 15 yeas experiences in silicone oil rotary damper, and we always control the quality from the very original material.
LF-33, ROTARY DAMPER, OPERATION ANGLE 110°, CLOCKWISE OR COUNTER CLOCKWISE, STAINLESS STEEL, 8-30 KGF.CM \BLK
1/ Design Torque:
3700-3800 damper 1.6 N.m.
1400-1700 damper 2.6 N.m.
2/ Damper units not to contain: Cadmium, Mercury, Lead, Chromium VI, PBB, PBDE (RoHS banned substances)
3/ Closing Time Test
Testing to be performed in conditions 20 +/-2
degrees C and 65 +/- 5 % Relative Humidity. Damper to be stored in this
environment a minimum of 2 hours before testing.
Set up torque arm to apply the design torque to
the damper (as per above)
Position 1: Measure the closing time from a
position of 70 degrees to 0 degrees (where 0 degrees is the closed position). The
closing time should be in the range of 6 to 12 sec.
Position 2: Measure the closing time from a
position 15 degrees to 0 degrees (where 0 degrees is the closed position). The
closing time should be 0.4 sec or more.
Repeat the closing time test for both positions on
30 dampers and record the results.
4/ High Temperature test –
Expose damper to an atmosphere of 50+/-5 degrees
C for 96 hours. Remove damper and store at 20 +/-2 degrees C and 65 +/- 5 %
Relative Humidity for 1 hour.
Perform closing time test at design torque for that model damper
Damper shall pass closing time test
5/ Low Temperature test –
Expose damper to an atmosphere of -10+/-5
degrees C for 96 hours. Remove damper and store at 20+/-2 degrees C and 65 +/-
5 % Relative Humidity for 1 hour.
Perform closing time test at design torque for that model damper
Damper shall pass closing time test.
6/ Humidity Test-
Expose damper to an atmosphere of 90+/-5 % RH
for 96 hours. Remove damper and store at 20 +/-2 degrees C and 65 +/- 5 %
Relative Humidity for 1 hour.
Perform closing time test at design torque for that model damper
Damper shall pass closing time test.
7/ Thermal Shock Test
Expose damper to 5 thermal shock cycles as
follows: -10 degrees C for 7.5 hrs, 20 degrees C for 0.5 hrs, 50 degrees C for
15.5 hrs (24h/ cycle)
Remove damper and store at 20 +/-2 degrees C and
65 +/- 5 % Relative Humidity for 1 hour.
Perform closing time test at design torque for that model damper
Damper shall pass closing time test.
8/ Life Cycle Test
Damper units to be assembled with toilet seat
and tested on open /close cycle tester. Machine lifts ring and cover to above
70 degrees and allows ring and cover to fall to fall to 0 degrees before
starting the next cycle.- Lid and cover to pass 50,000 cycles without
damage or breaking of dampers. If slow close time falls below 2 sec (for ring
or cover) before 50,000 cycles are complete this is considered a failure.
Packaging Detail:55 pcs per plastic plate, 10 pcs plastic plates per carton, 550 pcs per carton, net weight 8.5 kgs, gross weight 9.2 kgs. carton size: 38 * 33 *23 cm. |
Delivery Detail:20-25days |