HG-001 Thermostatic cartridge with Vernet element - HG-001
1. Vernet Element, 2. Comply with ASSE1016, EN1111/1287, AS-4032.1, 3. Advanced Imported Test System, 4. Long life circle - details see: https://www.buildingsupplieshub.com/hg-001-thermostatic-cartridge-with-vernet-element-10063358
Type: Faucet Cartridges | Place of Origin: Guangdong China (Mainland) | Brand Name: HANER | Model Number: HG-001 |
Material: HPB 59-1 | Function: Temperature Control | Turn: 270 ° | Lifelong Cycles: 300,000 |
Safety Stop: 38°C |
HG-Series brass thermostatic cartridges comply with the following standard: ASMEA112.1812005/CSAB125.1-05, ASSE1016, EN1111, AS-4032.1 and QB2806-2006.
Component and material
Description | Material |
Spindle | BS (HPB59-1) |
Spindle Guide | BS (HPB59-1) |
E-Ring | SUS304 |
O-Ring | NBR |
Housing | BS (HPB59-1) |
Washer | POM |
Spring | SUS304 |
Spring Cap | BS (HPB59-1) |
Strainer | SUS304 |
Stopper | ABS |
Element | Vernet Element |
TECHNICAL DATA
Limit of Use | Recommend limits for correct operation | |
Dynamic Pressure | 0.5 bar min. | 1 bar ≤ P ≤ 5 bar |
Static Pressure | 10 bar max. | |
Hot Water Temperature | T ≤ 90 °C | 55 °C ≤ T ≤ 65 °C |
Cold Water Temperature | T ≤ 25°C | |
Temperature Safety Stop | 38 °C or 40 °C | |
Life cycle | ≥100,000 cycles | |
Temperature Accuracy | ±1.5°C |
Outlet Flow Rate at specified temperature at 3 bar (avg. data of 30 samples)
Full cold position | 34 °C | 38°C | 42°C | Full hot position | |
Flow Rate | 23 l/min | 25 l/min | 30 l/min | 25 l/min | 22 l/min |
Discharged hot water volume as cold water failure (average data of 30 samples)
Five 5 seconds | 30 seconds | |
Discharged hot water volume | 60ml | 80ml |
Temperature Stability as Inlet water pressure and temperature changes ( average data of 30 samples)
Packaging Detail:1. EPE Packing for each cartridge. 2. 50 PCS per carton. |
Delivery Detail:25 - 30 days |