Energy-saving 1600KG passenger lift elevator - GPRS20
Energy-saving 1600KG passenger lift elevator, 1.Delivery within 30days, 2.VVVF drive, 3.CE,ISO9001,ISO14001 approved - details see: https://www.buildingsupplieshub.com/energy-saving-1600kg-passenger-lift-elevator-10060641
Type: Elevator Parts | Place of Origin: Zhejiang China (Mainland) | Brand Name: SRH Passenger Elevator | Model Number: GPRS20 |
Certificate: ISO 9001, ISO14001,CE | Capacity(kg): 400-1600 | Speed(m/s): 1.0-4.0 | Persons: 6,8,10,13,15,16,18,21 |
Max traveling height: 180meters | Max stops: 48 | Car & Door decoratation: stainless steel,painted steel,glass | Floor: PVC |
FOR PRODUCTS:
1600kg Passenger Elevator Feature:
1.small machine room, 50% space saving,reduced construction cost;Machine roomless lift also available.
2.Efficient and 30% energy saving;
3.Humanized design, comfort and natural;
4.Double VVVF driver , stable and reliable;
5.Green environmental, automatic lighting of LED energy-saving lamp;
6.Low noise;
7.Top advanced door operator system;
8.Slide + roller composite guide shoe;
9.Automatic special door machine, synchronous timing belt transmission, TUV and CE Certification passed
1600kg Passenger ElevatorAvailable Specification:
Persons | Rated Capacity (KG) | Rated Speed (m/s) | Net size of car(mm) | Net size of door(mm) | Hoistway size (mm) | Machine room size(mm) | Max traveling height (m) | |||
C.WxC.D | D.WxD.H 2p center opening | H.WxH.D | HR.H | P.H | MR.WxMR.D | MR.H | ||||
16 | 1250 | 1 | 1950x1400 | 1100x2100 | 2600x2020 | 4500 | 1500 | 2300x2120 | 2900 | 45 |
1.6/1.75 | 4600 | 1700 | 96 | |||||||
2 | 4900 | 1800 | 120 | |||||||
2.5 | 5100 | 2000 | 150 | |||||||
3 | 5600 | 2600 | 150 | |||||||
3.5 | 5950 | 3100 | 180 | |||||||
4 | 6350 | 3850 | 180 | |||||||
Persons | Rated Capacity (KG) | Rated Speed (m/s) | Net size of car(mm) | Net size of door(mm) | Hoistway size (mm) | Machine room size(mm) | Max traveling height (m) | |||
C.WxC.D | D.WxD.H 2p center opening | H.WxH.D | HR.H | P.H | Machine Roomless | |||||
16 | 1250 | 1 | 1950x1400 | 1100x2100 | 2600x2020 | 4500 | 1500 | 45 | ||
1.6/1.75 | 4600 | 1700 | 96 | |||||||
2 | 4900 | 1800 | 120 |
Standard Function | ||
Travel Function | VVVF drive | Motor rotating speed can be precisely adjusted to get smooth speed curve in lift start,travel and stop and gain the sound comfort. |
VVVF door operator | Motor rotating speed can be precisely adjusted to get the more gentle and sensitive door machine start/stop | |
Independent running | The lift only respond to the command inside the car through the action switch | |
Automatic pass without stop | When the car is crowded with the passenger or the load is close to preset value,the car will automatically pass the calling landing in order to keep maimum travel efficiency | |
Automatically adjust door opening time | Door-open time can be automatically adjusted according to the difference between landing calling or car calling | |
Reopen with hall call | In the door shutting process,press reopen with hall call button can restart the door | |
Express door closing | When the lift stops and opens the door, press door-shut button,the door will be closed immediately | |
Car stops and door open | The lift decelerates and levels,the door only opens after the lift comes to a complete stop | |
Car arrival gong | Arrival gong in the car top announces that the passengers arrive | |
Command register cancel | If you press the wrong floor coomand button in the car, twice continuous pressing of the same button can cancel the registered command | |
Direct parking | It completely accords with distance principle with no crawling in the leveling. It greatly enhances the travel efficiency | |
Safety function | Photecell reptection | In the door open and shut period,infrared light that covers the whole door height is used to probe the door protection device of both the passengers and objects |
Designated stop | If the lift can not open the door in the destination floor out of some reason,the lift will close the door and travel to the next designated floor | |
Overload holding stop | When the car is overload,the buzzer rings and stops the lift in the same floor | |
Anti-stall timer protection | The lift stops operation due to slippery traction wire rope | |
Start protection control | If the lift does not leave door zone within the designated time after it gets started,it will stop the operation | |
Inspection operation | When the lift enters into inspection operation,the car travels at inching running | |
Fault self-diagnosis | The controller can record 62 latest troubles so as to quickly remove the trouble and restore the lift operation | |
Repeated door closing | If the lift can not close the door due to certain obstacle or interference, the lift will reopen or re-shut the door until sundries results in more safe and reliable lift travel | |
Up/down over-run and final limit protection | The device can effectively prevent from the lift's surging to the top or knocking the bottom when it is out of control.It results in more safe and reliable lift travel | |
Down over-speed protection device | When the lift downs 1.2 times higher than the rated speed, this device will automatically cut off control mains,stop the motor running so as to stop lift down at over-speed. If the lift continues to down at over-speed, and the speed is 1.4 times higher than rated speed, safety tongs act to force the lift stop in order to ensure the safety | |
Upward over-speed protection device | When the lift up speed is 1.2 times higher than rated speed, the device will automatically decelerate or brake the lift | |
Man-machine interface | Micro-touch button for car call and hall call | Novel micro-touch button is used for operation panel command button in the car and landing calling button |
Floor and direction indicatior inside car | The car shows the lift floor location and current travel direction | |
Floor and direction indicator in hall | The landing shows the lift floor location and current travel direction | |
Emergency function | Emergency car lighting | Emergency car lighting automatically activated once power failure |
Inching running | When the lift enters into emergency electric operation,the car travels at low speed inching running | |
Five way intercom | Communication amid car,car top,lift machine room,well pit and rescue duty room through walkie-talkie | |
Fire emergency return | If you start key switch in main landing or monitor screen,all the callings will be cancelled.The lift directly and immediately drives to the designated rescue landing and automatically opens the door | |
Energy-saving function | Car ventilation, light automatic shut off | If there is no calling or command signal within the stipulated time, the car fan and lighting will be automatically closed in order to save the energy |
Remote shut-off | The lift can be called to main landing(after finishing the service) through the key switch and automatically exists the service |
Optional functions also offered according to your special request.
Drawings for reference:
For any demand pls kindly informed,e-catalogue and quoatation will offered then.
Packaging Detail:Standard export wooden packing. Special packing demand could also meet. |
Delivery Detail:45-60days after receiving the deposit or L/C |