electric heating cable - ALTGV(GG)2R

1,safety,, 2,comfortable and health, 3.extremely long service life without maintenance, 4,energy-saving - details see: https://www.buildingsupplieshub.com/electric-heating-cable-10068637
Place of Origin: SIC,sichuan,china China (Mainland)Brand Name: ANLTModel Number: ALTGV(GG)2RType: Floor Heating Parts,electric heating cable
Floor Heating Part Type: Floor Heating Cablesbrand: Anltjacket: PVCVoltage: 220V
electric heating cable
contact supplier for electric heating cable


Specifi

cation

Power
(W/M)
Voltage
(V)
Normal
Resistance
LengthTotal Power
(w/roll)
Specifi

cation

Power
(W/M)
Voltage
(V)
Normal
Resistance
LengthTotal Power
(w/roll)

ALTGV1R Single
Lead

18220161.3316.7300

ALTGV2R

Double
Lead

18220161.3316.7300
1822012122.24001822012122.2400
1822096.827.85001822096.827.8500
1822080.6733.36001822080.6733.3600
1822069.1438.97001822069.1438.9700
1822056.9447.28501822056.9447.2850
1822048.455.610001822048.455.61000
1822038.417012601822038.41701260
1822035.5975.6613601822035.5975.661360
1822030.2588.916001822030.2588.91600
1822027.597.817601822027.597.81760
1822024.2111.120001822024.2111.12000
1822022122.222001822022122.22200
1822020.17133.324001822020.17133.32400
1822018.62144.426001822018.62144.42600
1822017.29155.62800/////
1822016.13166.73000/////

prodution process:

some samples :

office and workshop:

certifates:

Frequently Asked Questions

Q:Is there electromagnetic radiation to the human body by using ANLT Floor Heating System?

A:The heating cable of ANLT Heating Cable Floor Radiant Heating System adopts the double-screen construction,can effectively reduce the electromagnetic radiation,so it is very safe and will not produce electromagnetic radiation on the human body.

Q:Does the cable have the electric-leakage problem ?

A:The electric heating products lack of strict quality control and application experience may have hidden danger of electric leakage.But ANLT heating cable uses the sophisticated design and production technology,with the multiple safe protection devices such as the electric-leakage protection,so it can be assured for safe use.

Q:Dose ANLT Heating Cable Floor Radiant Heating System have huge power consumption ?

A:The power consumption of ANLT Heating Cable Floor Radiant Heating System depends on many factors such as the hours of use,temperature setting ,and heating conservation,and intelligent temperature control system,you can save huge electricity bills.

Q:What’s the difference between ANLT Heating Cable Floor Radiant Heating System and traditional hot-water heating system ?

A:The structure of ANLT Heating Cable Floor Radiant Heating System is simple,temperature of the room is more even,temperature control is more accurate too,in addition,for comparing,the hot-water heating system has the disadvantages of the difficult of sectional temperature control and huge investment on installation;the heating temperature is different too,hot-water system has a highter temperature but having a higher requirement for the floor materials

Q:Which are the requirements for installing the ANLT Heating Cable Floor Radiant Heating System?

A:It is very simple for installation,only need a certain height of the structure layer,including heat-conservation layer,generally about 3-5 centimeters. In addition,for safety requirement,you need certain power capacity installation.

Q:How long will it last ?

A:The ANLT Heating Cable products provide 12 years’ quality guarantee.According to different operating conditions ,the whole heating system can be used for 50 years without maintenance.

Q:What are the main difference between ANLT Heating Cable Floor Radiant Heating System and traditional heating system ?

A:It is more comfortable by using ANLT Heating Cable Floor Radiant Heating System than the traditional heating system; ANLT Heating system adopts the “invisible installation”,which will not impact the decoration of the internal design of your houses;temperature in different rooms can be controlled separately;without noise impace and dry feeling.

Q:What are the floor material requirements for installing the ANLT Heating Cable Floor Radiant Heating System ?

A:Many kinds of floor materials can be used for installing ANLT Heating Cable Floor Radiant Heating System.Such as ceramic tiles and marbles,which distribute the temperature fast and provide most comfortable feeling.

Packaging Detail:electric heating cable As requested
Delivery Detail:15 working days after order confirmed

Related Product for electric heating cable