Electric Cable Heating Floor 220V - RX-heating cable

Electric Cable Heating Floor 220V, 1.Rated voltage: 220V 50Hz, 2.Pressure:300/500V, 3.Linear power:17W/M,18W/M,20W/M - details see: https://www.buildingsupplieshub.com/electric-cable-heating-floor-220v-10068759
Place of Origin: Guangdong China (Mainland)Brand Name: szrunxiangModel Number: RX-heating cableType: Floor Heating Systems
Heating Conductor: Copper-nickel alloyOutside Insulation: PETOuter Jacket: PVC - Polyvinyl ChlorideThickness: 1.35±0.05mm
Diameter: 6.50 +/- 0.30 mmProducts Name: Electric Cable Heating Floor 220V  
Electric Cable Heating Floor 220V
contact supplier for Electric Cable Heating Floor 220V


Electric Cable Heating Floor 220V

Electrical parameters

1.Rated voltage: 220V 50Hz (voltage can be customized)

2.Pressure:300/500V

3.Linear power:17W/M,18W/M,20W/M

4.Cold wire length:2 Root × 2.25m

5.Minimum bending radius:5×Cable diameter

Product structure

Heating Conductor

Shield

MaterialCopper-nickel alloy

Outside insulation

FormPatchPolyester belt formLongitudinal layer of polyester
Number7 RootPolyester materialPET
DiameterΦ 0.30±0.02 mmPolyester belt specifications0.25×12 mm
Cable Core1 CoreBraid materialTC - Tinned Copper

Insulation

Braid16×3×TCΦ0.10 mm
MaterialSilicone rubberCovered≥ 35%
Thickness1.00±0.05 mm

Braid outside

DiameterΦ 3.00±0.10 mmPolyester belt formLongitudinal layer of polyester
Number and color1 Root:Transparent ColorPolyester materialPET
MarkingPer Customer RequestPolyester belt specifications0.25×14 mm

Outer Jacket

MaterialPVC - Polyvinyl ChlorideThickness1.35±0.05mm
ColorBlue & RedDiameter6.50 +/- 0.30 mm

Electrical Performance

Reference Standard:

1.JGJ 142—2004 Technical specification for floor radiant heating

2.IEC 60800:1992 Rated voltage 300/500V heating cable for life

facility heating and guards against

Test Item Unit Spec

1.Product temperature cable voltages 2.0 kV/5min No breakdown

2.Product temperature cable voltages (100 °C) 1.5 kV/15min No breakdown

3.Min.Subsequent insulation resistance (100°C) MΩ·km 0.03

4.Standard resistor errors (20°C) Ω/m -5% ~ +10%

5.Temperature coefficient of resistance Should be a positive number

6.Maximum grounding resistance (20°C) Ω/m ≤0.0181

7.Continuity of conductors, shielded — Continuous