Data center raised floor standards - RF005

Data center raised floor standards, Cement infill steel, Anti-static, OA/trunk floor - details see: https://www.buildingsupplieshub.com/data-center-raised-floor-standards-10073480
Type: Other FlooringPlace of Origin: China (Mainland)Brand Name: LDSModel Number: RF005
Data center raised floor standards
contact supplier for Data center raised floor standards


Cement Infill Steel Raised Access Floor

l Research& Development

Patent Design Cross Strengthening Rib

10%- 30% improved in loading capacity compared with competing products

Flatness increased by 10%

l Type 1

OA Network Raised Access Floor

  1. 500mm OA Network Raised Access Floor
  2. 600mm OA Network Raised Access Floor

l Application

5A class office, security union plaza, futures trading building, places demanding cabling and wiring and the aging buildings’ flooring reform

l Characteristic

Full steel structure, high quality cement infill

Panel surface painted with conductive Epoxy Resin

Lock holes in 4 corners

Unique patent design “Cross Strengthening Rib”

Recyclable, convenient removing, cost saving, long performance life

Size: 500×500×28mm 600×600×35mm/ 24×24inch×35mm

Model

Concentrated load

Impact load

(N)

Ultimate load

(N)

Uniform

Load

(N/m2)

Rolling load(N)

LBNKG10 times100000

times

FS440≥440≥1960≥200≥295≥5880≥972019581566
FS662≥662≥2950≥301≥445≥8850≥1250029462356
FS800≥800≥3350≥363≥536≥11250≥1610035602670
FS1000≥1000≥4550≥453≥670≥13350≥2300044503560
FS1250≥1250≥5560≥567≥780≥16680≥3300055604450
FS1500≥1500≥6675≥680≥1005≥19892≥4300066755340


l Type 2

Trunking OA Network Raise Access Floor

  1. 500mm Trunking OA Network Raised Access Floor
  2. 600mm Trunking OA Network Raised Access Floor

l Application

5A class office, security union plaza, futures trading building, places demanding cabling and wiring and the aging buildings’ flooring reform

l Characteristic

Flexible trunks for wiring and cabling

High recyclability, convenient removing, saving cost, long performance life

Patent design

l Under Structure

Aluminum Head Pedestal

Galvanized Steel Tube

l Aluminum head: 56/ 71mm

l Steel Base:80/ 95mm

l Tube diameter:21, 25mm

l Tube thickness:1.2, 1.5, 2.0mm

l Screw diameter:16/ 18mm

l Gasket on top, Nut lock


l After sale:

10 yearsof warranty in which new floors would be sent if there’s any damage.

Flooring solutionandInstallation instructionis available. Our engineer would give on-site instruction if possible.